{"id":19419,"date":"2017-02-10T10:14:23","date_gmt":"2017-02-10T09:14:23","guid":{"rendered":"https:\/\/delta-engineering.be\/?p=19419"},"modified":"2023-01-19T10:59:23","modified_gmt":"2023-01-19T09:59:23","slug":"preform-spray-coater","status":"publish","type":"post","link":"https:\/\/marketing.delta-engineering.be\/delta\/preform-spray-coater","title":{"rendered":"DSC054"},"content":{"rendered":"<h2 class=\"m_title\">Preform spray coater<\/h2>\n\n&nbsp;<\/p>\n<h4><strong>Design<\/strong><\/h4>\n<p>Whereas our bottle spray coaters (<a href=\"\/?p=2263\" target=\"_blank\" rel=\"noopener noreferrer\">DSC100<\/a>, <a href=\"\/?p=27038\" target=\"_blank\" rel=\"noopener noreferrer\">DSC200<\/a>) coats the bottle directly, the preform spray coater DSC054 <strong>coats the preforms <\/strong>by<strong> spraying <\/strong>them<strong> in the&nbsp;infeed bin <\/strong>of the preforms.<\/p>\n<p>This can be done on different locations:<\/p>\n<h5><strong>&#8211; <span style=\"text-decoration: underline;\">In the injection process<\/span>:<\/strong><\/h5>\n<p>As the <strong>preforms<\/strong> are <strong>falling into the preform bin<\/strong>, the spray coater sprays a shot in the bin. The amount of product and frequency of the shots&nbsp;are adjustable.<br \/>\n&nbsp;<\/p>\n<h5><strong>&#8211; <span style=\"text-decoration: underline;\">During the bin filling<\/span>:<\/strong><\/h5>\n<p>When buying preforms externally, you can <strong>mount the unit on the preform bin<\/strong>. When the <strong>preforms<\/strong> are <strong>tipped into the bin<\/strong>, we give a couple of shots during this process. Again configurable in time and quantity.<\/p>\n<p>The downside of this system, however, is that the product can and will go on the inside of the preform and it should be 100% food grade.<br \/>\nTherefore, we at Delta Engineering are not advising this technology, especially for food &amp; pharma applications.<br \/>\n&nbsp;<\/p>\n<h4><strong>The machine<\/strong><\/h4>\n<p>This unit is a <strong>4-head preform spray coater<\/strong>, <strong>mounted over the infeed bin of the preforms<\/strong>. It sprays the preforms as they are falling into the preform bin.<\/p>\n<p>Optionally, we also have an <strong>extraction hood<\/strong> to extract all particles, with a blowoff outside or with a carbon filter cartridge to capture them.<br \/>\nPlease read our <a href=\"\/?p=17930\" target=\"_blank\" rel=\"noopener noreferrer\">article importance of fume extraction<\/a>.<\/p>\n<p>&nbsp;<\/p>\n<h4><strong>ADVANTAGES<\/strong><\/h4>\n<ul>\n<li>Resolves all sticking issues on the filling lines.<\/li>\n<li>Easy setup and short change-over times thanks to the recipes<\/li>\n<li>Small footprint<\/li>\n<li>Low cost<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h4><strong>OTHER VERSIONS<\/strong><\/h4>\n<p>Bottle spray coater: <span style=\"text-decoration: underline;\"><a title=\"DSC100\" href=\"\/?p=2263\" target=\"_blank\" rel=\"noopener noreferrer\">DSC100<\/a><\/span>, <span style=\"text-decoration: underline;\"><a title=\"DSC200\" href=\"\/?p=27038\" target=\"_blank\" rel=\"noopener noreferrer\">DSC200<\/a><\/span><br \/>\n\n\n\n\n\n\n\nRESOURCES\n\n\n\n","protected":false},"excerpt":{"rendered":"<p><b>Preform spraying system<\/b><\/p>\n<p>This spray coater with 4 heads is mounted over the infeed bin of the preforms. It sprays coating on the preforms as they are falling into the bin.<\/p>\n","protected":false},"author":1688,"featured_media":19427,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[1891],"tags":[],"_links":{"self":[{"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/posts\/19419"}],"collection":[{"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/users\/1688"}],"replies":[{"embeddable":true,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/comments?post=19419"}],"version-history":[{"count":27,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/posts\/19419\/revisions"}],"predecessor-version":[{"id":39076,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/posts\/19419\/revisions\/39076"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/media\/19427"}],"wp:attachment":[{"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/media?parent=19419"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/categories?post=19419"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/tags?post=19419"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}