{"id":23340,"date":"2018-10-17T11:56:16","date_gmt":"2018-10-17T09:56:16","guid":{"rendered":"https:\/\/delta-engineering.be?p=23340"},"modified":"2024-11-28T08:23:20","modified_gmt":"2024-11-28T07:23:20","slug":"plasma-coater-containers","status":"publish","type":"post","link":"https:\/\/marketing.delta-engineering.be\/delta\/plasma-coater-containers","title":{"rendered":"DPC613"},"content":{"rendered":"<h2 class=\"m_title\">Plasma coater for containers<\/h2>\n\n&nbsp;<\/p>\n<h4><strong>What is plasma coating?<\/strong><\/h4>\n<p>PECVD is short for &#8216;plasma enhanced chemical vapour deposition&#8217;. It uses electrical discharge (in a low vacuum pressure condition) to <strong>decompose a gas<\/strong>. By doing so, it <strong>creates a thin coating layer on the inside wall of the product<\/strong>.<\/p>\n<p>Besides, plasma coating is an environmentally friendly way to create fully recyclable coated products. They can have different physical and\/or chemical properties. These depend on the material and the plasma gas used.<\/p>\n<p>You can obtain different properties:<\/p>\n<ul>\n<li><strong>modify<\/strong> the <strong>surface tension<\/strong> for <strong>better sliding, adhesion, wettability<\/strong><\/li>\n<li><strong>improve<\/strong> the <strong>barrier<\/strong> in different applications: <strong>migration, permeation&#8230;<\/strong><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h4><strong>Plasma coating, the environmentally friendly approach!<\/strong><\/h4>\n<p>As you may know, new legislation is on its way. It will require ambitious <strong>recycling of packaging material<\/strong>.<br \/>\nThat is challenging for multilayers, because they provide good barrier properties, but are non-recyclable because of their different, inseparable layers.<br \/>\nOur plasma coater can create <strong>better barrier properties than multilayers<\/strong>. But you may consider it as a <strong>monolayer packaging<\/strong>.<\/p>\n<p>It is <strong>easy to grind the coated material and recycle<\/strong> it, together with non-coated materials:<\/p>\n<ul>\n<li>The <strong>percentage<\/strong> of our <strong>coating<\/strong> is <strong>negligible<\/strong> to that of the plastic packaging: 60 to 150 nanometers.<\/li>\n<li>The coating will be <strong>largely removed during the washing process<\/strong>.<\/li>\n<li>Coated bottles will not reach a market penetration much higher than 10 %. As a result, this <strong>rules out a change in flake quality<\/strong> in the recycling plants.<\/li>\n<\/ul>\n<p>We <strong>only use environmentally friendly gases<\/strong> for plasma coating.<br \/>\n&nbsp;<br \/>\nFurthermore, the gases are largely consumed during the process, <strong>reducing the exhaust<\/strong> to a minimum. In addition, an <strong>active carbon filter<\/strong> can easily capture the remainder of the gases, should local legislation require this.<br \/>\n&nbsp;<\/p>\n<h4><strong>The machine<\/strong><\/h4>\n<p>The DPC613 can <strong>coat containers from 3L up to 15L<\/strong>. The machine inserts the products into a vacuum chamber, after having vacuumized both.<\/p>\n<p>This plasma coater for containers can use 2 technologies:<\/p>\n<ul>\n<li>Carbon deposition on PET containers. This results in an improved O2 ( &gt;30x) barrier, CO2 ( &gt;7x) and H20 ( &gt;2x).<\/li>\n<li>Carbon Fluor deposition. This results in a \u00e2\u20ac\u02dcfluorinated\u00e2\u20ac\u2122 container without actually using any Fluor.<\/li>\n<\/ul>\n<p>This machine has 6 vacuum chambers. It can treat around <strong>700-800 BPH (HDPE)<\/strong> or <strong>1050-1600 BPH (PET)<\/strong>, depending on the process and volume.<br \/>\nHowever, these speeds are indicative, so please use our <a href=\"\/?p=24466\" target=\"_blank\" rel=\"noopener noreferrer\">calculation tool<\/a> to simulate the exact speed, power and gas consumption.<\/p>\n<p>This plasma coater for containers uses proprietary technology. Therefore, we only disclose limited info on our website. So please contact us for more information.<\/p>\n<p>We can develop specific barrier processes depending on your needs.<\/p>\n<p>&nbsp;<\/p>\n<h4><strong>ADVANTAGES<\/strong><\/h4>\n<ul>\n<li>Weight reduction of the container<\/li>\n<li>We can adjust the barrier to your needs<\/li>\n<li>100 % recyclable<\/li>\n<li>Can treat PET &amp; HDPE containers<\/li>\n<li>On PET: Improved Oxygen barrier<\/li>\n<li>On HDPE: Improved Solvent barrier<\/li>\n<\/ul>\n<p>Please download our <a href=\"\/\/marketing.delta-engineering.be\/delta\/wp-content\/uploads\/2020\/06\/Plasma-coating-brochure_UK_2019_V1.pdf\" rel=\"noopener noreferrer\" target=\"_blank\">Technology brochure<\/a> for a full overview.<br \/>\n&nbsp;<\/p>\n<h4><strong>OTHER VERSIONS<\/strong><\/h4>\n<p>Plasma coater for containers: <span style=\"text-decoration: underline;\"><a title=\"DPC123\" href=\"\/?p=23230\" target=\"_blank\" rel=\"noopener noreferrer\">DPC123<\/a><\/span>, <span style=\"text-decoration: underline;\"><a title=\"DPC223\" href=\"\/?p=23245\" target=\"_blank\" rel=\"noopener noreferrer\">DPC223<\/a><\/span>, <span style=\"text-decoration: underline;\"><a title=\"DPC413\" href=\"\/?p=23268\" target=\"_blank\" rel=\"noopener noreferrer\">DPC413<\/a><\/span><br \/>\nPlasma coater for bottles: <a title=\"DPC403\" href=\"\/?p=25354\" target=\"_blank\" rel=\"noopener noreferrer\">DPC403<\/a><br \/>\nL Ring plasma coater for drums: <a title=\"DPC133\" href=\"\/?p=28258\" target=\"_blank\" rel=\"noopener noreferrer\">DPC133<\/a><br \/>\n\n\n\n\n\n\n\nPRICE\n\n\n\nRESOURCES\n\n\n\n","protected":false},"excerpt":{"rendered":"<p><b>Plasma coater for containers<\/b><\/p>\n<p>This plasma coater can coat plastic containers from 3L up to 15L. It creates a barrier on the inside of PET (1050-1600 BPH) and HDPE (700-800 BPH) containers. Fully recyclable coating. Machine with 6 vacuum chambers.<\/p>\n","protected":false},"author":1,"featured_media":26949,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[1880],"tags":[],"_links":{"self":[{"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/posts\/23340"}],"collection":[{"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/comments?post=23340"}],"version-history":[{"count":16,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/posts\/23340\/revisions"}],"predecessor-version":[{"id":42200,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/posts\/23340\/revisions\/42200"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/media\/26949"}],"wp:attachment":[{"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/media?parent=23340"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/categories?post=23340"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/tags?post=23340"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}