{"id":28770,"date":"2020-06-04T15:04:11","date_gmt":"2020-06-04T13:04:11","guid":{"rendered":"https:\/\/delta-engineering.be?p=28770"},"modified":"2024-05-14T17:05:10","modified_gmt":"2024-05-14T15:05:10","slug":"high-voltage-leak-tester-1-head","status":"publish","type":"post","link":"https:\/\/marketing.delta-engineering.be\/delta\/high-voltage-leak-tester-1-head","title":{"rendered":"UDK461"},"content":{"rendered":"<h3 class=\"m_title\">High voltage leak tester \u00e2\u20ac\u201c 1 head<\/h3>\n\nHigh voltage leak tester for the leak testing of micro cracks in the <strong>gate area of PET bottles<\/strong>.<\/p>\n<h4><strong>Design<\/strong><\/h4>\n<p>The bottles are running into the machine on a conveyor belt. When the bottle reaches the test position photocell, the bottle stops and is grabbed by the neck.<br \/>\nOnce in position, the test rod lowers into the bottle. When the test rod is down, we apply the testing voltage between the base and the inside of the bottle, starting the test cycle.<br \/>\nAfter the leak test, the head goes up and the bottle is conveyed further on the conveyor. If there is a crack detected in the gate area, the bottle will be rejected immediately.<br \/>\n\nADVANTAGES\n\n<ul>\n<li>The machine has a short change-over time. Parameters can be loaded from recipes.<\/li>\n<li>Designed for big products 1-30L PET bottles, speeds up to 800-1000 BPH.<\/li>\n<li>The modularity of the machine enables you to go to high speeds within the same product family. This reduces the cost of ownership in spare parts and training of the operators, the benefits from standardisation @ Delta Engineering through the different equipments.<\/li>\n<li>Multiple doors: easily accessible, less space needed on the product floor.<br \/>\n\nOTHER VERSIONS\n\nLeak tester for bottles: <a title=\"UDK050\" href=\"\/?p=1901\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"text-decoration: underline;\">UDK050<\/span><\/a>, <span style=\"text-decoration: underline;\"><a title=\"UDK055\" href=\"\/?p=16801\" target=\"_blank\" rel=\"noopener noreferrer\">UDK055<\/a><\/span>, <a title=\"UDK250\" href=\"\/?p=1911\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"text-decoration: underline;\">UDK250<\/span><\/a>, <a title=\"UDK310\" href=\"\/?p=1928\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"text-decoration: underline;\">UDK310<\/span><\/a><br \/>\nLeak tester for bottles \u00e2\u20ac\u201c high speed: <a title=\"UDK351\" href=\"\/?p=1963\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"text-decoration: underline;\">UDK351<\/span><\/a>, <a title=\"UDK352\" href=\"\/?p=1980\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"text-decoration: underline;\">UDK352<\/span><\/a>, <a title=\"UDK353\" href=\"\/?p=1998\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"text-decoration: underline;\">UDK353<\/span><\/a>, <a title=\"UDK354\" href=\"\/?p=2001\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"text-decoration: underline;\">UDK354<\/span><\/a><br \/>\nLeak tester for drums: <span style=\"text-decoration: underline;\"><a title=\"UDK060\" href=\"\/?p=26562\" target=\"_blank\" rel=\"noopener noreferrer\">UDK060<\/a><\/span><br \/>\nLeak tester for IBC: <a title=\"UDK500\" href=\"\/?p=1942\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"text-decoration: underline;\">UDK500<\/span><\/a><br \/>\nHigh-voltage leak tester for PET bottles: <a title=\"UDK451\" href=\"\/?p=2022\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"text-decoration: underline;\">UDK451<\/span><\/a>, <a title=\"UDK452\" href=\"\/?p=27834\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"text-decoration: underline;\">UDK452<\/span><\/a>, <a title=\"UDK453\" href=\"\/?p=27851\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"text-decoration: underline;\">UDK453<\/span><\/a>, <a title=\"UDK454\" href=\"\/?p=27854\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"text-decoration: underline;\">UDK454<\/span><\/a><br \/>\nRotary leak tester: <span style=\"text-decoration: underline;\"><a title=\"UDK616\" href=\"\/?p=21140\" target=\"_blank\" rel=\"noopener noreferrer\">UDK616<\/a><\/span><br \/>\nBuilt-in leak tester for bottles: <a title=\"ODK050\" href=\"\/?p=2716\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"text-decoration: underline;\">ODK050<\/span><\/a>, <a title=\"ODK250\" href=\"\/?p=1889\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"text-decoration: underline;\">ODK250<\/span><\/a>, <a title=\"ODK310\" href=\"\/?p=1895\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"text-decoration: underline;\">ODK310<\/span><\/a><br \/>\nBuilt-in leak tester for IBC: <a title=\"ODK500\" href=\"\/?p=2718\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"text-decoration: underline;\">ODK500<\/span><\/a><br \/>\n\nFAQ\n\nHow many bottles per hour can I test? Please check out our <span style=\"text-decoration: underline;\"><a title=\"Leak test calculator\" href=\"\/?p=3111\" target=\"_blank\" rel=\"noopener noreferrer\">leak test calculator<\/a><\/span><br \/>\nHow accurately can I test?<br \/>\n\nHow accurately can I test?<br \/>\n[\/dcontent]\nPRICE\n\n\n\nRESOURCES\n\n\n<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p><b>High voltage leak tester \u00e2\u20ac\u201c 1 head<\/b><\/p>\n<p>High voltage leak tester for the leak testing of micro cracks in the gate area of PET bottles.<\/p>\n","protected":false},"author":4146,"featured_media":28941,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[41],"tags":[],"_links":{"self":[{"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/posts\/28770"}],"collection":[{"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/users\/4146"}],"replies":[{"embeddable":true,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/comments?post=28770"}],"version-history":[{"count":3,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/posts\/28770\/revisions"}],"predecessor-version":[{"id":41896,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/posts\/28770\/revisions\/41896"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/media\/28941"}],"wp:attachment":[{"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/media?parent=28770"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/categories?post=28770"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/tags?post=28770"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}