{"id":34536,"date":"2020-10-16T12:47:32","date_gmt":"2020-10-16T10:47:32","guid":{"rendered":"https:\/\/delta-engineering.be?p=34536"},"modified":"2021-01-18T13:22:59","modified_gmt":"2021-01-18T12:22:59","slug":"micro-and-nano-ct-system","status":"publish","type":"post","link":"https:\/\/marketing.delta-engineering.be\/delta\/micro-and-nano-ct-system","title":{"rendered":"DXR120"},"content":{"rendered":"<h2 class=\"m_title\">Top performance large Micro and Nano CT System<\/h2>\n\n<div class=\"alignright\"><a rel=\"prettyPhoto[]\" class=\"hoverBorder pull-left scrolltotop\" href=\"\/\/marketing.delta-engineering.be\/delta\/wp-content\/uploads\/2020\/10\/DXR120-Top-performance-large-Micro-and-Nano-CT-System.png\"><span class=\"hoverBorderWrapper\"><img style=\"width: 150px;\" loading=\"lazy\" src=\"\/\/marketing.delta-engineering.be\/delta\/wp-content\/uploads\/2020\/10\/DXR120-Top-performance-large-Micro-and-Nano-CT-System-150x150.png\" alt=\"DXR120 - Top performance large Micro and Nano CT System\" width=\"150\" height=\"150\" class=\"size-thumbnail wp-image-36276\" \/><span class=\"theHoverBorder\"><\/span><\/span><\/a><\/div>\n<h4><strong>Need<\/strong><\/h4>\n<p><a href=\"http:\/\/en.wikipedia.org\/wiki\/X-ray_microtomography\" target=\"_blank\" rel=\"noopener noreferrer\">Microtomography<\/a> is a technique that has been used for a long time already in the medical world, which most of us have encountered already in the hospital: <a href=\"http:\/\/en.wikipedia.org\/wiki\/CT_scan\" target=\"_blank\" rel=\"noopener noreferrer\">CT scanning<\/a>.<\/p>\n<p>But did you know that you can use the same technique for bottles as well? Delta Engineering is now making this technology affordable for the blow moulding industry:<\/p>\n<p><strong>Microtomography<\/strong> allows you to:<\/p>\n<ul>\n<li><strong>Generate 3D drawings of products<\/strong> &#8211; &#8216;As is&#8217;: with all their characteristics and possible flaws.<br \/>\n        In the near future, we will offer online services to calculate top load, volume, oxygen &#038; CO2 barrier, etc (in an online platform). Moreover, it will be possible to use these data in process simulations, feeding back \u00e2\u20ac\u02dcbig data\u00e2\u20ac\u2122 to simulation systems.<\/li>\n<li><strong>Inspect for quality problems<\/strong>: for example, determining how much barrier material is present in a <strong>preform<\/strong><br \/>\n(see picture on the right)<\/li>\n<li>Improve your <strong>product analysis<\/strong>: for example, for weight reduction <div class=\"alignright\"><a rel=\"prettyPhoto[]\" class=\"hoverBorder pull-left scrolltotop\" href=\"\/\/marketing.delta-engineering.be\/delta\/wp-content\/uploads\/2020\/03\/CT-scans.png\"><span class=\"hoverBorderWrapper\"><img style=\"width: 300px;\" loading=\"lazy\" src=\"\/\/marketing.delta-engineering.be\/delta\/wp-content\/uploads\/2020\/03\/CT-scans-300x188.png\" alt=\"CT scans quality inspection\" width=\"300\" height=\"188\" class=\"size-medium wp-image-35404\" srcset=\"https:\/\/marketing.delta-engineering.be\/delta\/wp-content\/uploads\/2020\/03\/CT-scans-300x188.png 300w, https:\/\/marketing.delta-engineering.be\/delta\/wp-content\/uploads\/2020\/03\/CT-scans-280x176.png 280w, https:\/\/marketing.delta-engineering.be\/delta\/wp-content\/uploads\/2020\/03\/CT-scans.png 713w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><span class=\"theHoverBorder\"><\/span><\/span><\/a><\/div><\/li>\n<li><strong>Look into the product<\/strong>: for example, to detect assembly issues:\n<ul>\n<li>Is the cap closing everywhere?<\/li>\n<li>Detect internal leakage in pumping systems<\/li>\n<\/ul>\n<\/li>\n<li>And many more!<\/li>\n<\/ul>\n<p>&nbsp;<br \/>\n&nbsp;<br \/>\n&nbsp;<\/p>\n<h4><strong>The machine<\/strong><\/h4>\n<p>The DXR120 is a <strong>top performance large micro and nano CT system<\/strong> that collects complex internal and external geometry data.<\/p>\n<p>This CT scanner <strong>visualizes the complete bottle with extreme precision<\/strong>.<br \/>\nAs a result, you can do a <strong>fully automated quality inspection<\/strong>, measuring thickness, inclusions, presence of layers, etc.<\/p>\n<p><strong>Advantages<\/strong> of this top-performance micro and nano CT system:<\/p>\n<ul>\n<li><strong>Micro and nano<\/strong> mechanics and resolutions<\/li>\n<li>Specialized or combined high energy (230KV) and high resolution (nano) configurations<\/li>\n<li>Ideal for <a href=\"http:\/\/en.wiktionary.org\/wiki\/in_situ\" target=\"_blank\" rel=\"noopener noreferrer\">in-situ<\/a> scanning with easy access to the sample and test setup<\/li>\n<li>Flat panel detector or CCD camera<\/li>\n<\/ul>\n<div class=\"alignright\"><a rel=\"prettyPhoto[]\" class=\"hoverBorder pull-left scrolltotop\" href=\"\/\/marketing.delta-engineering.be\/delta\/wp-content\/uploads\/2020\/03\/Microtomography.png\"><span class=\"hoverBorderWrapper\"><img style=\"width: 150px;\" loading=\"lazy\" src=\"\/\/marketing.delta-engineering.be\/delta\/wp-content\/uploads\/2020\/03\/Microtomography-150x150.png\" alt=\"Microtomography\" width=\"150\" height=\"150\" class=\"size-thumbnail wp-image-34725\" \/><span class=\"theHoverBorder\"><\/span><\/span><\/a><\/div>\nSo how does this work exactly?<br \/>\nThe CT scanner uses X rays to beam through an object onto a receptor plate. By doing so, it generates a picture.<br \/>\nIt takes multiple pictures while the object is turning around. As a result, the pictures are processed into a 3D model. On this 3D model, several structural analyses and measurements can be made as well as optional CAD model export.<br \/>\n&nbsp;<\/p>\n<h4><strong>OTHER VERSIONS<\/strong><\/h4>\n<p>Compact Micro CT System: <span style=\"text-decoration: underline;\"><a title=\"DXR100\" href=\"\/?p=26330\" target=\"_blank\" rel=\"noopener noreferrer\">DXR100<\/a><\/span><br \/>\nHigh performance versatile Micro and Nano CT System: <span style=\"text-decoration: underline;\"><a title=\"DXR110\" href=\"\/?p=34533\" target=\"_blank\" rel=\"noopener noreferrer\">DXR110<\/a><\/span><br \/>\n\n\n\n\n\n\n\nPRICE\n\n\n\nRESOURCES\n\n\n\n","protected":false},"excerpt":{"rendered":"<p><b>Top performance large Micro &#038; Nano CT System<\/b><\/p>\n<p>This top performance micro &#038; nano CT system collects complex internal and external geometry data.<br \/>\nThe CT scanner visualizes the complete bottle with extreme precision. This allows you to do a fully automated quality inspection, etc.<\/p>\n","protected":false},"author":4146,"featured_media":36276,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[1835],"tags":[],"_links":{"self":[{"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/posts\/34536"}],"collection":[{"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/users\/4146"}],"replies":[{"embeddable":true,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/comments?post=34536"}],"version-history":[{"count":16,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/posts\/34536\/revisions"}],"predecessor-version":[{"id":36291,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/posts\/34536\/revisions\/36291"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/media\/36276"}],"wp:attachment":[{"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/media?parent=34536"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/categories?post=34536"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/marketing.delta-engineering.be\/delta\/wp-json\/wp\/v2\/tags?post=34536"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}